Column |
Column Title |
Description |
A |
Institution |
Anonymous version of institution name. |
B |
Machine |
Anonymous version of machine ID. |
C |
Acquisition |
Date and time that the first image in the data set was captured (delivery time). |
D |
Analysis |
Date and time that data was analyzed. |
E |
Procedure |
Procedure (test) used to process data |
F |
Beam Name MLC |
Name of RTPLAN MLC beam. |
G |
Beam Name Open |
Name of RTPLAN Open beam. |
H |
R LS -5.1 cm |
Avg CU of T3MLCSpeed for AOI centered at X = -5.1 cm |
I |
R LS -3.1 cm |
Avg CU of T3MLCSpeed for AOI centered at X = -3.1 cm |
J |
R LS -1.1 cm |
Avg CU of T3MLCSpeed for AOI centered at X = -1.1 cm |
K |
R LS 0.9 cm |
Avg CU of T3MLCSpeed for AOI centered at X = 0.9 cm |
L |
R LS 2.9 cm |
Avg CU of T3MLCSpeed for AOI centered at X = 2.9 cm |
M |
R LS 4.9 cm |
Avg CU of T3MLCSpeed for AOI centered at X = 4.9 cm |
N |
R LS 6.9 cm |
Avg CU of T3MLCSpeed for AOI centered at X = 6.9 cm |
O |
R Open -5.1 cm |
Avg CU of T3 Open for AOI centered at X = -5.1 cm |
P |
R Open -3.1 cm |
Avg CU of T3 Open for AOI centered at X = -3.1 cm |
Q |
R Open -1.1 cm |
Avg CU of T3 Open for AOI centered at X = -1.1 cm |
R |
R Open 0.9 cm |
Avg CU of T3 Open for AOI centered at X = 0.9 cm |
S |
R Open 2.9 cm |
Avg CU of T3 Open for AOI centered at X = 2.9 cm |
T |
R Open 4.9 cm |
Avg CU of T3 Open for AOI centered at X = 4.9 cm |
U |
R Open 6.9 cm |
Avg CU of T3 Open for AOI centered at X = 6.9 cm |
V |
R Corr -5.1 cm |
100 * LS / Open for AOI centered at X = -5.1 cm |
W |
R Corr -3.1 cm |
100 * LS / Open for AOI centered at X = -3.1 cm |
X |
R Corr -1.1 cm |
100 * LS / Open for AOI centered at X = -1.1 cm |
Y |
R Corr 0.9 cm |
100 * LS / Open for AOI centered at X = 0.9 cm |
Z |
R Corr 2.9 cm |
100 * LS / Open for AOI centered at X = 2.9 cm |
AA |
R Corr 4.9 cm |
100 * LS / Open for AOI centered at X = 4.9 cm |
AB |
R Corr 6.9 cm |
100 * LS / Open for AOI centered at X = 6.9 cm |
AC |
Diff(X) -5.1 cm |
R corr minus avg R corr for AOI centered at X = -5.1 cm |
AD |
Diff(X) -3.1 cm |
R corr minus avg R corr for AOI centered at X = -3.1 cm |
AE |
Diff(X) -1.1 cm |
R corr minus avg R corr for AOI centered at X = -1.1 cm |
AF |
Diff(X) 0.9 cm |
R corr minus avg R corr for AOI centered at X = 0.9 cm |
AG |
Diff(X) 2.9 cm |
R corr minus avg R corr for AOI centered at X = 2.9 cm |
AH |
Diff(X) 4.9 cm |
R corr minus avg R corr for AOI centered at X = 4.9 cm |
AI |
Diff(X) 6.9 cm |
R corr minus avg R corr for AOI centered at X = 6.9 cm |
AJ |
Avg of abs Diff(X) |
Average of absolute deviations (Diff Abs) |
AK |
Machine Type |
Type of machine |
AL |
Collimator |
Type of collimator |
AM |
EPID |
Type of EPID |
AN |
URL |
Link to main report. |
AO |
outputPK |
Internal database reference to synthetic public key of output. |
AP |
inputPK |
Internal database reference to synthetic public key of input. |
AQ |
Uploaded By |
Anonymized version of user ID. |
AR |
Pixel Rows |
Number of rows in the images. DICOM 0028,0010 |
AS |
Pixel Columns |
Number of columns in the images. DICOM 0028,0011 |
AT |
Pixel size X |
Image Plane Pixel Spacing. DICOM 3002,0011 |
AU |
Pixel size Y |
Image Plane Pixel Spacing. DICOM 3002,0011 |
AV |
b value for converting pixel values to CU: CU = m*PixelValue + b |
Rescale Intercept. DICOM 0028,1052 |
AW |
m value for converting pixel values to CU: CU = m*PixelValue + b |
Rescale Slope. DICOM 0028,1053 |
AX |
KVP |
Peak kilo voltage output of the X-Ray generator used. DICOM 0018,0060 |
AY |
Exposure Time msec |
Exposure time in mseync. DICOM 0016,0004 |
AZ |
Meterset Exposure |
Treatment machine Meterset duration over which image has been acquired, specified in Monitor units (MU) or minutes as defined by Primary Dosimeter Unit (300A,00B3). Required if Value 3 of Image Type (0008,0008) is PORTAL DICOM 3002,0032 |
BA |
Start Cumulative Meterset Wt |
Cumulative Meterset Weight within Beam referenced by Referenced Beam Number (300C,0006) at which image acquisition starts. DICOM 300C,0008 |
BB |
X-Ray Origin X |
Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
BC |
X-Ray Origin Y |
Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
BD |
X-Ray Origin Z |
Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
BE |
Source to Image |
Distance from radiation machine source to image plane (in mm) along radiation beam axis. DICOM 3002,0026 |
BF |
Source to Isocenter |
Radiation source to Gantry rotation axis distance of radiation machine used in acquiring or computing image (mm). DICOM 3002,0022 |
BG |
Gantry Angle |
Treatment machine gantry angle, i.e., orientation of IEC GANTRY coordinate system with respect to IEC FIXED REFERENCE coordinate system (degrees). DICOM 300A,011E |
BH |
Collimator Angle |
Treatment machine beam limiting device (collimator) angle, i.e., orientation of IEC BEAM LIMITING DEVICE coordinate system with respect to IEC GANTRY coordinate system (degrees). DICOM 300A,0120 |
BI |
End Cumulative Meterset Wt |
Cumulative Meterset Weight within Beam referenced by Referenced Beam Number (300C,0006) at which image acquisition ends. DICOM 300C,0009 |
BJ |
Beam Number |
Uniquely identifies the corresponding N-segment treatment beam specified by Beam Number (300A,00C0) within Beam Sequence (300A,00B0) in RT Beams Module within the RT Plan referenced in Referenced RT Plan Sequence (300C,0002) or the Ion Beam Sequence (300A,03A2) in the RT Ion Beams Module within the RT Ion Plan referenced in Referenced RT Plan Sequence (300C,0002). DICOM 300C,0006 |
BK |
Operator |
Anonymized name(s) of the operator(s) supporting the Series. DICOM 0008,1070 |
BL |
Software Version |
Manufacturer's designation of software version of the equipment that produced the sources. DICOM 0018,1020 |
BM |
SOPInstanceUID |
Uniquely identifies the SOP Instance. DICOM 0008,0018 |
BN |
SeriesInstanceUID |
Unique identifier for the Series that is part of the Study identified in Study Instance UID (0020,000D), if present, and contains the referenced object instance(s). DICOM 0020,000E |
BO |
PatientID |
Primary identifier for the Patient. DICOM 0010,0020 |
BP |
PatientName |
Patient's full name DICOM 0010,0010 |
BQ |
Open Pixel Rows |
Open Number of rows in the images. DICOM 0028,0010 |
BR |
Open Pixel Columns |
Open Number of columns in the images. DICOM 0028,0011 |
BS |
Open Pixel size X |
Open Image Plane Pixel Spacing. DICOM 3002,0011 |
BT |
Open Pixel size Y |
Open Image Plane Pixel Spacing. DICOM 3002,0011 |
BU |
Open b value for converting pixel values to CU: CU = m*PixelValue + b |
Open Rescale Intercept. DICOM 0028,1052 |
BV |
Open m value for converting pixel values to CU: CU = m*PixelValue + b |
Open Rescale Slope. DICOM 0028,1053 |
BW |
Open KVP |
Open Peak kilo voltage output of the X-Ray generator used. DICOM 0018,0060 |
BX |
Open Exposure Time msec |
Open Exposure time in mseync. DICOM 0016,0004 |
BY |
Open Meterset Exposure |
Open Treatment machine Meterset duration over which image has been acquired, specified in Monitor units (MU) or minutes as defined by Primary Dosimeter Unit (300A,00B3). Required if Value 3 of Image Type (0008,0008) is PORTAL DICOM 3002,0032 |
BZ |
Open Start Cumulative Meterset Wt |
Open Cumulative Meterset Weight within Beam referenced by Referenced Beam Number (300C,0006) at which image acquisition starts. DICOM 300C,0008 |
CA |
Open X-Ray Origin X |
Open Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
CB |
Open X-Ray Origin Y |
Open Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
CC |
Open X-Ray Origin Z |
Open Position in (x,y,z) coordinates of origin of IEC X-RAY IMAGE RECEPTOR System in the IEC GANTRY coordinate system (mm). See Note 2. DICOM 3002,000D |
CD |
Open Source to Image |
Open Distance from radiation machine source to image plane (in mm) along radiation beam axis. DICOM 3002,0026 |
CE |
Open Source to Isocenter |
Open Radiation source to Gantry rotation axis distance of radiation machine used in acquiring or computing image (mm). DICOM 3002,0022 |
CF |
Open Gantry Angle |
Open Treatment machine gantry angle, i.e., orientation of IEC GANTRY coordinate system with respect to IEC FIXED REFERENCE coordinate system (degrees). DICOM 300A,011E |
CG |
Open Collimator Angle |
Open Treatment machine beam limiting device (collimator) angle, i.e., orientation of IEC BEAM LIMITING DEVICE coordinate system with respect to IEC GANTRY coordinate system (degrees). DICOM 300A,0120 |
CH |
Open End Cumulative Meterset Wt |
Open Cumulative Meterset Weight within Beam referenced by Referenced Beam Number (300C,0006) at which image acquisition ends. DICOM 300C,0009 |
CI |
Open Beam Number |
Open Uniquely identifies the corresponding N-segment treatment beam specified by Beam Number (300A,00C0) within Beam Sequence (300A,00B0) in RT Beams Module within the RT Plan referenced in Referenced RT Plan Sequence (300C,0002) or the Ion Beam Sequence (300A,03A2) in the RT Ion Beams Module within the RT Ion Plan referenced in Referenced RT Plan Sequence (300C,0002). DICOM 300C,0006 |
CJ |
Open Operator |
Open Anonymized name(s) of the operator(s) supporting the Series. DICOM 0008,1070 |
CK |
Open Software Version |
Open Manufacturer's designation of software version of the equipment that produced the sources. DICOM 0018,1020 |
CL |
Open SOPInstanceUID |
Open Uniquely identifies the SOP Instance. DICOM 0008,0018 |
CM |
Open SeriesInstanceUID |
Open Unique identifier for the Series that is part of the Study identified in Study Instance UID (0020,000D), if present, and contains the referenced object instance(s). DICOM 0020,000E |
CN |
Open PatientID |
Open Primary identifier for the Patient. DICOM 0010,0020 |
CO |
Open PatientName |
Open Patient's full name DICOM 0010,0010 |
CP |
Note |
User defined note for this output. |